| dc.description.abstract |
Este trabalho realizou a instalação e análise da eficiência térmica de um trocador de
calor instalado no absorvedor de um concentrador solar linear Fresnel, localizado no
Instituto Federal de Educação, Ciência e Tecnologia – Campus Ibirubá. O trocador de
calor instalado possui quatro tubos de alumínio de diâmetro interno 9,53 mm e
comprimento 1 m, por onde circula água como fluido de trabalho. Para realizar o
cálculo da eficiência térmica são realizadas medições da temperatura de entrada do
fluido no trocador de calor, da temperatura de saída e da vazão, em duas situações:
circuito fechado, com recirculação de água e circuito aberto, sem recirculação de
água, ambos sob diferentes condições de irradiação. O trocador também foi avaliado
em duas situações de revestimento superficial: com e sem pintura de cor preta na
parte externa dos tubos. Os testes realizados em circuito fechado e sem o
revestimento superficial apresentaram uma eficiência média de absorção de calor de
17,80%. Ainda sem revestimento e com o circuito sem recirculação de água, a
eficiência média encontrada foi de 19,66%. Com a aplicação da pintura externa de cor
preta e com recirculação de água, a eficiência subiu para aproximadamente 25,30%,
em média. Por fim, sem recirculação de água e com pintura a eficiência média foi de
33,40%. Foi possível observar que a inclusão da pintura aumentou a diferença de
temperatura entre a saída e entrada do fluido de aproximadamente 1,82°C para
2,48°C, em média, melhorando significativamente a absorção de calor. A realização
deste trabalho permitiu concluir que é viável a instalação de um trocador de calor no
absorvedor de um concentrador solar linear do tipo Fresnel. Embora o aproveitamento
térmico tenha seja baixo, a solução representa uma alternativa promissora para o uso
da radiação solar no aquecimento térmico. |
pt_BR |
| dc.description.abstract |
This study involved the installation and analysis of the thermal efficiency of a heat
exchanger installed in the absorber of a Fresnel linear solar concentrator, located at
the Federal Institute of Education, Science and Technology – Ibirubá Campus. The
installed heat exchanger has four aluminum tubes with an internal diameter of 9.53
mm and a length of 1 m, through which water circulates as the working fluid. To
calculate the thermal efficiency, measurements are taken of the inlet temperature of
the fluid in the heat exchanger, the outlet temperature and the flow rate, in two
situations: closed circuit, with water recirculation and open circuit, without water
recirculation, both under different irradiation conditions. The exchanger was also
evaluated in two situations of surface coating: with and without black paint on the
outside of the tubes. The tests performed in a closed circuit and without the surface
coating showed an average heat absorption efficiency of 17.80%. Still without coating
and with the circuit without water recirculation, the average efficiency found was
19.66%. With the application of black external paint and water recirculation, the
efficiency increased to approximately 25.30%, on average. Finally, without water
recirculation and with paint, the average efficiency was 33.40%. It was possible to
observe that the inclusion of paint increased the temperature difference between the
fluid outlet and inlet from approximately 1.82°C to 2.48°C, on average, significantly
improving heat absorption. This work allowed us to conclude that it is feasible to install
a heat exchanger in the absorber of a Fresnel-type linear solar concentrator. Although
the thermal utilization is low, the solution represents a promising alternative for the use
of solar radiation in thermal heating. |
en |
| dc.format.mimetype |
application/pdf |
pt_BR |
| dc.language |
por |
pt_BR |
| dc.language.iso |
por |
pt_BR |
| dc.rights |
Open Access |
en |
| dc.subject |
Eficiência térmica |
pt_BR |
| dc.subject |
Radiação solar |
pt_BR |
| dc.subject |
Trocadores de calor |
pt_BR |
| dc.title |
Instalação e análise de um trocador de calor em um concentrador solar linear Fresnel |
pt_BR |
| dc.type |
Trabalho de conclusão de graduação |
pt_BR |
| dc.degree.grantor |
Instituto Federal de Educação, Ciência e Tecnologia do Rio Grande do Sul |
pt_BR |
| dc.degree.level |
Graduação |
pt_BR |
| dc.degree.date |
2025 |
pt_BR |
| dc.degree.local |
Ibirubá, BR-RS |
pt_BR |
| dc.degree.department |
Campus Ibirubá |
pt_BR |
| dc.degree.department |
Engenharia Mecânica |
pt_BR |